HEPA CAB PRESSURIZER - EXTERNAL/INTERNAL - FPS 55 Series

HEPA CAB PRESSURIZER - EXTERNAL/INTERNAL - FPS 55 Series - FULL KIT

No reviews
C$6,149.00Price

This compact unit is easy to install and requires minimal space. Every FPS 55 Series is factory vapor tested for integrity at .00038 micron, allowing CAF’s patented test procedure for validation. This same procedure, along with particulate testing, can be used to completely characterize environmental enclosure in the field. CAF has proven technology with over 30 years of experience.

 

FPS 55.2

  • Smallest quantifying system available in the market, 10.5” x 10” x 18”

  • Heavy duty powder coated metal construction

  • 12 volt or 24 volt DC

  • 50 CFM

  • Centrifugal pre-cleaner

  • Differential pressure gauge to correlate positive flow

  • cTUV, CE, CSA Certified

  • Factory system integrity test

  • Factory system performance test

  • Meets EN15695:category 4

 

FPS 55.1

  • Smallest quantifying system available in the market, 10.5” x 10” x 18”

  • Heavy duty powder coated metal construction

  • 115 volt AC

  • 50 CFM

  • Pre-cleaner options

  • Centrifugal pre-cleaner

  • Differential pressure gauge to correlate positive flow

  • Factory system integrity test

  • Factory system performance test

 

FPS 55.1-D

  • Attaches to FPS55.2

  • Added unit for filtration with heavy concentrations or specific vapors

  • 12 volt or 24 volt DC

  • 115 volt AC

  • 50 CFM

  • Factory system integrity test

  • Factory system performance test

 

System Operation

 

Airflow through the CAF FPS 55 Series system, with a CAF48R or CAF47R filter, is as follows:

 

1. Contaminated air is drawn into the system through the pre-cleaner. The circular motion of the pre-cleaner separates out larger particulates, dramatically increasing filter life.

 

2. Air passes through the three-stage primary filter.

  • Stage 1 is a standard PAPER media designed for the heavy dust environment of agricultural, industrial, mining, and off-road conditions. Also, the paper is superior in absorbing liquid aerosol droplets that are present in the air.

  • Stage 2 is respirator-grade ACTIVATED CARBON. The porous nature of this media effectively adsorbs organic vapors, such as diesel and chemical fumes. CAF’s customized, refined activated carbon works on surface area, and our patented design maximizes this principle.

  • Stage 3 is a sub-micron FINAL FILTER that provides protection of up to 99.998 @ 0.3µm while allowing maximum airflow.

 

3. Air exiting the FPS unit creates a positive flow of clean air inside a properly sealed cab. This positive flow pushes clean air out of the leaks in the micro-environment side of the system, rather than allowing contaminated air to enter. A differential pressure gauge is available to measure the difference in pressure between the inside and outside of the cab, monitoring flow rates and filter life.

 

Quantity
  • OEM Numbers

    FPS 55.2-12v,FPS 55.2-24v,FPS 55.1,FPS55.2,KA896052,896052, FPS55.2, FPS55.212V, 896052ATC

  • Related Parts

     

  • Generic

    Generic

  • Specifications

    CAF PARTICULATE SYSTEM / FILTER TEST PROCEDURE

    Laboratory / Field / Mine / Factory / Office / Residential

    An affordable methodology for quantifying filtration of airborne particulates on enclosed environments without an occupant. Directions / Protocol, using Optical Particle Counters (OPC) to determine (cab) protections factors. All OPC particulate testing is done at 0.3 micron (m). The range is 0.3 m to < 0.5 m. All cabs (operator micro environment) and filters, together or separate, in cab or in filter chamber, are tested at 0.3m at a range of 0.3m to < 0.5m for 30 minutes*a*b using the inside/outside ratio of the average of minutes #9 through #29. Cab leakage test minimum flow is 35.32 cfm (17.66 X 2) with a MPPS 99.95% filter or 99.98% @ 0.3m filter. First Test, as is, or / and If more than one fan speed, test at High and Low Test flow rate and cab protection factors If HVAC recirculation filter is used, test as is, or / and If more than one fan speed, test at High and Low Test flow rate and cab protection factors Test on both fresh and dirty recirculation filter (plugged is worst case scenario). Record on OPC test report: Voltage Temperature Engine RPM Windspeed, direction and orientation of cab If cab pressure is under 0.05” H2 O pressure use multidirectional testing to determine worst case scenario

  • Product Classification

    AIR

  • Category Data

    Installation Kit

Vehicle Search

Air Conditioning

Air Conditioning

Reefers

Reefers

Heating

Heating

Air Filters

Air Filters

Energy

Energy

Equipment

Equipment

PRODUCT DETAILS

HEPA CAB PRESSURIZER - EXTERNAL/INTERNAL - FPS 55 Series
bestseller.png
HEPA CAB PRESSURIZER - EXTERNAL/INTERNAL - FPS 55 Series
HEPA CAB PRESSURIZER - EXTERNAL/INTERNAL - FPS 55 Series
HEPA CAB PRESSURIZER - EXTERNAL/INTERNAL - FPS 55 Series
HEPA CAB PRESSURIZER - EXTERNAL/INTERNAL - FPS 55 Series

Financing Options Available
(Over C$7,500)

Item #

FPS55

HEPA CAB PRESSURIZER - EXTERNAL/INTERNAL - FPS 55 Series - FULL KIT

average rating is 4.8 out of 5, based on 18 votes, Product ratings

List price: US$4,477.99

Select your option(s) 

Installation
See Details
See Details
Voltage
See Details
See Details
Service Cab Pressurization
See Details
See Details

Payment:

Secure Transaction

png-clipart-visa-mastercard-american-express-paypal-logos-tech-companies-payments.png

Review our Business

KABAIR ALTERNATIVE

SKU

Title

Price

View Product

  Description

This compact unit is easy to install and requires minimal space. Every FPS 55 Series is factory vapor tested for integrity at .00038 micron, allowing CAF’s patented test procedure for validation. This same procedure, along with particulate testing, can be used to completely characterize environmental enclosure in the field. CAF has proven technology with over 30 years of experience.

 

FPS 55.2

  • Smallest quantifying system available in the market, 10.5” x 10” x 18”

  • Heavy duty powder coated metal construction

  • 12 volt or 24 volt DC

  • 50 CFM

  • Centrifugal pre-cleaner

  • Differential pressure gauge to correlate positive flow

  • cTUV, CE, CSA Certified

  • Factory system integrity test

  • Factory system performance test

  • Meets EN15695:category 4

 

FPS 55.1

  • Smallest quantifying system available in the market, 10.5” x 10” x 18”

  • Heavy duty powder coated metal construction

  • 115 volt AC

  • 50 CFM

  • Pre-cleaner options

  • Centrifugal pre-cleaner

  • Differential pressure gauge to correlate positive flow

  • Factory system integrity test

  • Factory system performance test

 

FPS 55.1-D

  • Attaches to FPS55.2

  • Added unit for filtration with heavy concentrations or specific vapors

  • 12 volt or 24 volt DC

  • 115 volt AC

  • 50 CFM

  • Factory system integrity test

  • Factory system performance test

 

System Operation

 

Airflow through the CAF FPS 55 Series system, with a CAF48R or CAF47R filter, is as follows:

 

1. Contaminated air is drawn into the system through the pre-cleaner. The circular motion of the pre-cleaner separates out larger particulates, dramatically increasing filter life.

 

2. Air passes through the three-stage primary filter.

  • Stage 1 is a standard PAPER media designed for the heavy dust environment of agricultural, industrial, mining, and off-road conditions. Also, the paper is superior in absorbing liquid aerosol droplets that are present in the air.

  • Stage 2 is respirator-grade ACTIVATED CARBON. The porous nature of this media effectively adsorbs organic vapors, such as diesel and chemical fumes. CAF’s customized, refined activated carbon works on surface area, and our patented design maximizes this principle.

  • Stage 3 is a sub-micron FINAL FILTER that provides protection of up to 99.998 @ 0.3µm while allowing maximum airflow.

 

3. Air exiting the FPS unit creates a positive flow of clean air inside a properly sealed cab. This positive flow pushes clean air out of the leaks in the micro-environment side of the system, rather than allowing contaminated air to enter. A differential pressure gauge is available to measure the difference in pressure between the inside and outside of the cab, monitoring flow rates and filter life.

 

  Specifications

CAF PARTICULATE SYSTEM / FILTER TEST PROCEDURE

Laboratory / Field / Mine / Factory / Office / Residential

An affordable methodology for quantifying filtration of airborne particulates on enclosed environments without an occupant. Directions / Protocol, using Optical Particle Counters (OPC) to determine (cab) protections factors. All OPC particulate testing is done at 0.3 micron (m). The range is 0.3 m to < 0.5 m. All cabs (operator micro environment) and filters, together or separate, in cab or in filter chamber, are tested at 0.3m at a range of 0.3m to < 0.5m for 30 minutes*a*b using the inside/outside ratio of the average of minutes #9 through #29. Cab leakage test minimum flow is 35.32 cfm (17.66 X 2) with a MPPS 99.95% filter or 99.98% @ 0.3m filter. First Test, as is, or / and If more than one fan speed, test at High and Low Test flow rate and cab protection factors If HVAC recirculation filter is used, test as is, or / and If more than one fan speed, test at High and Low Test flow rate and cab protection factors Test on both fresh and dirty recirculation filter (plugged is worst case scenario). Record on OPC test report: Voltage Temperature Engine RPM Windspeed, direction and orientation of cab If cab pressure is under 0.05” H2 O pressure use multidirectional testing to determine worst case scenario